Water Jet Pump Wont Start?- Tuesday, January 13, 2015

There are a number of issues that a Jet Pump can have. Among those issues there are a few that are quite common. We are going to go over some common issues to check that will most likely get you’re your Water Pump up and running if it will not start at all.

 

-The Zone Valve may not be opening. This makes it so that water can’t flow through the Pump. Check to see if your Water Systems pressure has dropped. If so this could definitely be your issue.

- Check the Circuit Breaker. Check all of the circuits and wires to see if any wires are disconnected or if you can see obvious damage.

-Is your Motor Set to the correct Voltage? This mistake happens a lot more than one might think. There is usually a switch that you can toggle between the motors different voltage options. (This is assuming that you don’t have a Single Speed Pump.)

- Check Wiring on motor.  Just like you checked the Circuit Breakers wires, now you want to check the actual wiring on the motor.

- Not getting any Voltage? Make sure to see how much, if any, voltage you are getting from the side of your motor. If you are not getting any voltage the pressure switch could be the issue.

Tags :  troubleshootingjet pumpmyersstariteissuesvoltage
Comments (0)
A Brief History Of FE Myers Water Pumps- Tuesday, December 9, 2014

Myers Florida Pump Service

Myers Water Pumps are some of the most popular Pumps in the U.S and abroad. They revolutionized the Water Pump Industry and made many very important technological advancements. Here’s a look at their history.

After the Civil War there were many opportunities for those with ambition and Francis E. Myers was among them. In 1870 Francis and his brother Philip stopped working on their father’s farm and began “The F.E. Myers & Bro. Company”. Francis and Philip both played very important roles in the company’s success. Francis was known as a great sales person and was able to handle the business end of things while Philip was acknowledged as a “mechanical genius “.

FE Myers caught its first break when they patented a Double Action Pump. The pump allowed water to flow in a stream instead of coming out erratically. Although the Double Action Pump was successful, FE Myers big break happened after they patented a Water Pump with a special glass vale seat that would not leak or corrode. The design was wildly popular and forced Myers competitors to purchase it through them.  

Myers Glass Valve Seat Patent

With the success of their patents and designed the Myers brothers needed help and brought on their other two brothers, Alvah and Denton. The company continued to grow and just 12 years after starting the company boasted having 30,000 dealers that were selling their water pumps. Fe Myers died in 1923 and left the company in the hands of Philip who then passed away in 1932. FE Myers continued its success even through the stock market crash of 1929.

In the 1950’s the demand for household water pumps was dwindling so Myers began manufacturing Water Filtration and Water Softening Systems. They also saw a demand for more efficient water pumps and began manufacturing them. Myers was sold to McNeil Machine and Engineering Co. in 1960. Twenty Six years later Pentair Inc purchased McNeil and still sells Myers Brand Pumps today.

Reference: 

A History of F.E. Myers and Bro., By Jan Shellhouse,http://goo.gl/FWLaeP

Tags :  MyersWater PumpJet PumpHistory
Comments (0)